CE Marked. PRIMEPET and SUREPETTE series pipettes meet your needs for acccuracy and precision. Single/Multi Channel available.

Performance Specifications

When used in accordance with the pipetting procedures in the manual and with our tips, PRIMEPET®s will perform to the below specifications.

   Model     Accuracy   Precision
   Volume Range     Normal Volume(mean error)  (repeatability)
             μl              μl        %          %
PP - 10           1 - 101 * ±4≤2.5
  5±2≤1.0
  10±1.5≤0.8
PP - 20           2 - 202±5≤1.5
  10±2≤1.0
  20±2≤0.8
PP - 100          20 - 10020±2≤1.0
  50±1.2≤0.5
  100±1.2≤0.3
PP - 200          50 - 20050±2≤1.0
  100±1.0≤0.7
  200±1.0≤0.5
PP - 1000        100 - 1000100±1.5≤0.8
  500±0.9≤0.4
  1000±0.9≤0.28
PP - 5000        1000 - 50001000±1.1≤0.4
  2000±0.7≤0.3
  5000±0.7≤0.2

.

*Only for the practiced.

NOTES:

1.      Accuracy is the closeness of a measured volume to the true volume as specified by the volume setting of the pipette. Also known as mean error.

2.      Precision is the scatter of individual measurements around the mean of a large number of replicate measurements of the same volume. Also known as standard deviation.

When used in accordance with the pipetting procedures in the Users Guide and with our tips, SUREPETTE® s will perform to the below specifications.

Adjustable Volume Pipettes

  Model

     &        

Volume   Range 

Normal VolumeAccuracyPrecision
(mean error)(repeatability)
   μl     %       %
SPA - 101 * ±12≤4.0
   1~10 μl5±6.4≤3.0
 10±3.2≤2.0
SPA - 505±6.4≤3.0
   5~50 μl25±3.0≤2.0
 50±2.4≤1.5
SPA - 10010±3.2≤2.0
10~100μl50±2.4≤1.5
 100±1.5≤1.0
SPA - 20050±2.4≤1.5
50~200μl100±1.5≤1.0
 200±1.5≤1.0
SPA - 1000200±1.5≤1.0
200~1000500±1.5≤0.5
μl1000±1.2≤0.5
SPA - 50001000±1.2≤0.5
1000~50002000±1.0≤0.5
μl5000±1.0≤0.5

*  Only for the practiced.

Fixed Volume Pipettes

 Normal AccuracyPrecision
Model Volume(mean error)(repeatability)
 μl%%
SPF-55±4.8≤3.0
SPF-1010±3.0≤2.0
SPF-2020±2.4≤1.0
SPF-2525±2.4≤1.0
SPF-5050±2.4≤1.0
SPF-100100±1.5≤0.8
SPF-200200±1.2≤0.7
SPF-250250±1.2≤0.7
SPF-500500±1.2≤0.7
SPF-10001000±1.0≤0.5
SPF-20002000±1.0≤0.5
SPF-50005000±1.0≤0.5

micro pipette