- Contact Person : Ms. Karen Liu
- Company Name : AccuBioTech Co., Ltd.
- Tel : 0086-10-62058220
- Fax : 0086-10-62055579
- Address : Beijing,Beijing,No. 28, Yu Hua Road,
- Country/Region : China
- Zip : 101300
Related Product Searches:micro pipette,High Quality,micropipette, micropipette,pipette
Performance Specifications
When used in accordance with the pipetting procedures in the manual and with our tips, PRIMEPET®s will perform to the below specifications.
Model | Accuracy | Precision | ||
Volume Range | Normal Volume | (mean error) | (repeatability) | |
μl | μl | % | % | |
PP - 10 | 1 - 10 | 1 * | ±4 | ≤2.5 |
5 | ±2 | ≤1.0 | ||
10 | ±1.5 | ≤0.8 | ||
PP - 20 | 2 - 20 | 2 | ±5 | ≤1.5 |
10 | ±2 | ≤1.0 | ||
20 | ±2 | ≤0.8 | ||
PP - 100 | 20 - 100 | 20 | ±2 | ≤1.0 |
50 | ±1.2 | ≤0.5 | ||
100 | ±1.2 | ≤0.3 | ||
PP - 200 | 50 - 200 | 50 | ±2 | ≤1.0 |
100 | ±1.0 | ≤0.7 | ||
200 | ±1.0 | ≤0.5 | ||
PP - 1000 | 100 - 1000 | 100 | ±1.5 | ≤0.8 |
500 | ±0.9 | ≤0.4 | ||
1000 | ±0.9 | ≤0.28 | ||
PP - 5000 | 1000 - 5000 | 1000 | ±1.1 | ≤0.4 |
2000 | ±0.7 | ≤0.3 | ||
5000 | ±0.7 | ≤0.2 |
.
*Only for the practiced.
NOTES:
1. Accuracy is the closeness of a measured volume to the true volume as specified by the volume setting of the pipette. Also known as mean error.
2. Precision is the scatter of individual measurements around the mean of a large number of replicate measurements of the same volume. Also known as standard deviation.
When used in accordance with the pipetting procedures in the Users Guide and with our tips, SUREPETTE® s will perform to the below specifications.
Adjustable Volume Pipettes
Model & Volume Range | Normal Volume | Accuracy | Precision |
(mean error) | (repeatability) | ||
μl | % | % | |
SPA - 10 | 1 * | ±12 | ≤4.0 |
1~10 μl | 5 | ±6.4 | ≤3.0 |
10 | ±3.2 | ≤2.0 | |
SPA - 50 | 5 | ±6.4 | ≤3.0 |
5~50 μl | 25 | ±3.0 | ≤2.0 |
50 | ±2.4 | ≤1.5 | |
SPA - 100 | 10 | ±3.2 | ≤2.0 |
10~100μl | 50 | ±2.4 | ≤1.5 |
100 | ±1.5 | ≤1.0 | |
SPA - 200 | 50 | ±2.4 | ≤1.5 |
50~200μl | 100 | ±1.5 | ≤1.0 |
200 | ±1.5 | ≤1.0 | |
SPA - 1000 | 200 | ±1.5 | ≤1.0 |
200~1000 | 500 | ±1.5 | ≤0.5 |
μl | 1000 | ±1.2 | ≤0.5 |
SPA - 5000 | 1000 | ±1.2 | ≤0.5 |
1000~5000 | 2000 | ±1.0 | ≤0.5 |
μl | 5000 | ±1.0 | ≤0.5 |
* Only for the practiced.
Fixed Volume Pipettes
Normal | Accuracy | Precision | |
Model | Volume | (mean error) | (repeatability) |
μl | % | % | |
SPF-5 | 5 | ±4.8 | ≤3.0 |
SPF-10 | 10 | ±3.0 | ≤2.0 |
SPF-20 | 20 | ±2.4 | ≤1.0 |
SPF-25 | 25 | ±2.4 | ≤1.0 |
SPF-50 | 50 | ±2.4 | ≤1.0 |
SPF-100 | 100 | ±1.5 | ≤0.8 |
SPF-200 | 200 | ±1.2 | ≤0.7 |
SPF-250 | 250 | ±1.2 | ≤0.7 |
SPF-500 | 500 | ±1.2 | ≤0.7 |
SPF-1000 | 1000 | ±1.0 | ≤0.5 |
SPF-2000 | 2000 | ±1.0 | ≤0.5 |
SPF-5000 | 5000 | ±1.0 | ≤0.5 |
micro pipette